HVE Publications and Awards

 

 

 

2016

Conferences

  1. H. Zainuddin, “Challenges in condition monitoring,” MyHVnet Newsletter - Special focus on 2016 MyHVnet Colloquium, pp. 11-12, 2016.
  2. N.A. Othman, H. Zainuddin and A. Aman, “A comparative study of creepage discharge phenomena between palm and mineral oils,” MyHVnet Newsletter - Special focus on 2016 MyHVnet Colloquium, 2016, pp. 48, 2016.
  3. M.S. Mohamad, H. Zainuddin, S.A. Ghani and I.S. Chairul, “Study of breakdown voltage of palm oil based nanofluids,” MyHVnet Newsletter - Special focus on 2016 MyHVnet Colloquium, pp. 49, 2016.
  4. M.A. Abdullah, A. Aman and H. Zainuddin, “Thermal and leakage current behaviour of polymeric material under the effect of conductivity, flowrate and voltage,” MyHVnet Newsletter - Special focus on 2016 MyHVnet Colloquium, pp. 50, 2016.
  5. M.H.S. Zainoddin, H. Zainuddin and A. Aman,“Study of breakdown behaviour of mineral oil with suspended cellulose particles under DC voltage,” MyHVnet Newsletter - Special focus on 2016 MyHVnet Colloquium, pp. 55, 2016.
  6. M.H.S. Zainoddin, H. Zainuddin and A. Aman,“Study of breakdown behaviour of ester oil with suspended cellulose particles under direct current voltage,” in Proceedings of Mechanical Engineering Research Day 2016, pp. 92-93, 2016.
  7. H. Zainuddin, S.N. Norhan and N.A. Othman, “Investigation of surface breakdown on various solid insulation immersed in ester and mineral oils under ac stress,” in Proceedings of Mechanical Engineering Research Day 2016, pp. 179-180, 2016.

 

 

Journals

  1. N. Abu Bakar and A. Abu-Siada, "A novel method of measuring transformer oil interfacial tension using UV-Vis spectroscopy," in IEEE Electrical Insulation Magazine, vol. 32, no. 1, pp. 7-13, January-February 2016.

 

 

2015

Conferences

  1. Imran Sutan Chairul, Yasmin Hanum Md Thayoob, Young Zaidey Yang Ghazali, Mohd Shahril Ahmad Khiar, Sharin Ab Ghani, “Formation and Effect of Moisture Contents to Kraft Paper’s Life of In-Service Power Distribution Transformer,” Applied Mechanics and Materials, Vol. 793, 2015, pp.114-118. (SCOPUS INDEXED)
  2. S.A. Ghani, N.A. Muhamad and H. Zainuddin, “Performance Of Palm Shell Activated Carbon As Alternative Adsorbent For Reclamation Of Used Transformer Oil,” ARPN Journal of Engineering and Applied Sciences, Vol. 10, No. 22, pp. 10752-10758, 2015.
  3. M. S. Mohamad, H. Zainuddin, S. A. Ghani and I. S. Chairul, "AC breakdown voltage of natural ester mixed with Iron Oxide for oil-immersed power transformer application," 2015 IEEE Student Conference on Research and Development (SCOReD), Kuala Lumpur, Malaysia, 2015, pp. 16-20.
  4. H. Zainuddin and P.L. Lewin, “Modeling of Degradation Mechanism at the Oil-Pressboard Interface due to Surface Discharge,” in Proceeding of the COMSOL Confference, 2015.
  5. N.A. Othman, H. Zainuddin, A. Aman, S.A. Ghani, M.S.A. Khiar, I.S. Chairul and M.A. Talib, “Moisture effect on the crepage discharge phenomena on cellulosed-based pressboard immersed in palm fatty acid ester,” in International Conference on Power, Energy and Communication Systems (IPECS), Perlis, Malaysia, 24-25August 2015, pp. 458-464.
  6. M.H.S. Zainoddin, H. Zainuddin and A. Aman, “Investigation of bridging phenomena in ester oils contaminated with cellulose particles,” in International Conference on Power, Energy and Communication Systems (IPECS), Perlis, Malaysia, 24-25August 2015, pp. 408-413.
  7. Aminudin Aman, Muhammad Azwadi Bin Abdullah and Hidayat Zainuddin, “ Feasibility of Thermal Characteristic as Diagnostic Tool for Polymeric Insulation Surface Condition”, International Conference on Power, Energy and Communication Systems (IPECS) 2015, 2015.

 

 

Journals

  1. N. A. Baka, A. Abu-Siada, S. Islam and M. F. El-Naggar, "A new technique to measure interfacial tension of transformer oil using UV-Vis spectroscopy," in IEEE Transactions on Dielectrics and Electrical Insulation, vol. 22, no. 2, pp. 1275-1282, April 2015.
  2. S. Ab Ghani, Y. H. Md Thayoob, Y. Z. Yang Ghazali, M. S. Ahmad Khiar, I. Sutan Chairul, M. S. Mohamad, "Comparative Study of Worldwide Standards for Interpreting Frequency Response Analysis (FRA) Results of Distribution Transformers", Applied Mechanics and Materials, Vol. 793, pp. 144-148, 2015.

 

 

2014

Conferences

  1. S. A. Ghani, M. S. Ahmad Khiar, I. S. Chairul, M. Y. Lada and N. H. Rahim, "Study of magnetic fields produced by transmission line tower using finite element method (FEM),"Technology, Informatics, Management, Engineering, and Environment (TIME-E), 2014 2nd International Conference on, Bandung, 2014, pp. 64-68.
  2. M. S. A. Khiar, S. A. Ghani, I. S. Chairul, Y. H. M. Thayoob and Y. Z. Y. Ghazali, "On-site OLTC monitoring using duval triangle and DWRM," Technology, Informatics, Management, Engineering, and Environment (TIME-E), 2014 2nd International Conference on, Bandung, 2014, pp. 216-221.
  3. F. Hanaffi et al., "Evaluation of grounding grid's effective area," Lightning Protection (ICLP), 2014 International Conference o, Shanghai, 2014, pp. 402-406.
  4. Sharin Ab Ghani, Yasmin Hanum Md Thayoob, Young Zaidey Yang Ghazali, Mohd Shahril Ahmad Khiar, Imran Sutan Chairul and Mohd Safwan Mohamad, “Comparative Study of Worldwide Standards for Interpreting Frequency Response Analysis (FRA) Results of Distribution Transformers”, International Conference on Electrical Power Engineering & Applications 2014.
  5. Mohd Shahril Ahmad Khiar, Yasmin Hanum Md Thayoob, Young Zaidey Yang Ghazali, Sharin Ab Ghani, and Imran Sutan Chairul, “On-Site OLTC Monitoring Using Duval Triangle and DWRM”, 2nd International Conference on Technology, Informatics, Management, Engineering & Environment, 2014, pp. 216-221.

 

 

Journals

  1. N. A. Bakar, A. Abu-Siada and S. Islam, "A review of dissolved gas analysis measurement and interpretation techniques," in IEEE Electrical Insulation Magazine, vol. 30, no. 3, pp. 39-49, May-June 2014.

 

 

2012

Conferences

  1. N. H. Rahim, I. Sutan Chairul, S. Ab Ghani, M. S. Ahmad Khiar, N. Abas and Y. H. Md Thayoob, "Simulation of TDR circuit for the analysis of wave propagation in XLPE cable model," 2012 IEEE International Conference on Power and Energy (PECon), Kota Kinabalu, 2012, pp. 796-801.
  2. S. Ab Ghani, Y. H. Md Thayoob, Y. Z. Y. Ghazali, M. S. A. Khiar and I. S. Chairul, "Evaluation of transformer core and winding conditions from SFRA measurement results using statistical techniques for distribution transformers," 2012 IEEE International Power Engineering and Optimization Conference (PEOCO), Melaka, Malaysia, 2012, pp. 448-453.
  3. I. Sutan Chairul, S. Ab Ghani, M. S. Ahmad Khiar, Y. H. Md Thayoob and Y. Z. Yang Ghazali, "Kraft paper insulation's life assessment and effects of oxygen and moisture to paper insulation's deterioration rate," 2012 IEEE International Conference on Power and Energy (PECon), Kota Kinabalu, 2012, pp. 728-731.
  4. M. S. A. Khiar, Y. H. Md Thayoob, Y. Z. Y. Ghazali, S. Ab Ghani and I. S. Chairul, "Condition assessment of OLTC using duval triangle and static winding resistance test," 2012 IEEE International Power Engineering and Optimization Conference (PEOCO), Melaka, Malaysia, 2012, pp. 432-435.
  5. H. Zainuddin, P. L. Lewin and P. M. Mitchinson, "Characteristics of leakage current during surface disharge at the oil-pressboard interface," 2012 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Montreal, QC, 2012, pp. 483-486.
  6. A. Aman and M. Yaacob, "Optimization of dielectric strength of polymeric composite insulation using Response Surface Methodology," 2012 IEEE International Conference on Power System Technology (POWERCON), Auckland, 2012, pp. 1-5.
  7. A. Aman, A. R. Abdullah and M. Yaacob, "Dielectric property of Waste Tire Dust-Polypropylene (WTD-PP) composite for high voltage outdoor insulation application," 2012 IEEE International Power Engineering and Optimization Conference (PEOCO) Melaka, Malaysia, 2012, pp. 124-128.
  8. Zainuddin, H, Lewin, P L and Mitchinson, P M (2012), "Measurement of Leakage Current at the Oil-Pressboard Interface during Surface Discharge." In, The Fifth UHVnet Colloquium, University of Leicester, Leicester, UK, 18 - 19 Jan 2012. , 24.

 

 

 

 

 

 

 

INTERNAL LINKS

 

 

  

 

 

 

 

 

 

 

© 2018 CeRIA | UTeM

 

 

 

 

 

 EXTERNAL LINKS

 

 

 

 

 

 

 

 

 

CONTACT US

CENTER OF ROBOTICS AND INDUSTRIAL AUTOMATION

FACULTY OF ELECTRICAL ENGINEERING

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

HANG TUAH JAYA76100 DURIAN TUNGGAL

MELAKA

phone: +606 555 2344/2212

fax: +606 555 2222

email: ceria@utem.edu.my

 

 

 

 

 

Please publish modules in offcanvas position.